{"product_id":"deye-gb-w-pack12-2-a3-235ah-12-03kwh-51-2vdc-230a-ip20","title":"Deye GB-W-Pack12-2-A3 235Ah,12.03kWh,51.2Vdc,230A , IP20","description":"\u003cp\u003eDEYE GB-W-Pack12-2-A3 is high performance\u003cstrong\u003eLiFePO₄ (LFP) battery module\u003c\/strong\u003ewith nominal energy\u003cstrong\u003e12.03 kWh\u003c\/strong\u003e, capacity\u003cstrong\u003e235 Ah\u003c\/strong\u003eand rated voltage\u003cstrong\u003e51.2 VDC\u003c\/strong\u003e. The module is the main power component of the high voltage modular system\u003cstrong\u003eDEYE GB-W\u003c\/strong\u003e, designed for higher capacity residential systems and small to medium commercial and industrial C\u0026amp;I applications.\u003c\/p\u003e\n\u003cp\u003eThe battery modules are connected\u003cstrong\u003esequentially\u003c\/strong\u003e, and depending on their number, a system of\u003cstrong\u003e60.1 to 192.5 kWh\u003c\/strong\u003e. The modular design allows for easy stacking of the battery cluster, and the system is designed to work with DEYE high-voltage hybrid inverters from\u003cstrong\u003e30 to 125 kW\u003c\/strong\u003e, as well as with 100\/125 kW PCS solutions.\u003c\/p\u003e\n\u003cp\u003eGB-W-Pack12-2-A3 supports maximum continuous charge\/discharge current\u003cstrong\u003e230 A\u003c\/strong\u003e. The GB-W series uses a multi-level safety system, including thermal insulation at the cell level, an aerosol fire extinguishing system at the battery pack level, and dual temperature monitoring of the cells and electrical connections.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003eMain advantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eLiFePO₄ (LFP) battery technology\u003cbr\u003eNominal energy of one module: 12.03 kWh\u003cbr\u003eNominal capacity: 235 Ah\u003cbr\u003eRated voltage: 51.2 VDC\u003cbr\u003eMaximum charge\/discharge current: 230 A\u003cbr\u003eModular high voltage architecture\u003cbr\u003eFrom 5 to 16 battery modules in one GB-W cluster\u003cbr\u003eSystem capacity from 60.1 to 192.5 kWh\u003cbr\u003eRecommended depth of discharge: 90% DoD\u003cbr\u003e≥6000 cycles under the conditions specified by the manufacturer\u003cbr\u003eCell and battery pack level balancing\u003cbr\u003eThermal insulation at cell level\u003cbr\u003eAerosol fire protection at battery pack level\u003cbr\u003eDual temperature monitoring\u003cbr\u003eNatural air cooling of the system\u003cbr\u003eCAN \/ RS485 communication of the battery system\u003cbr\u003eDegree of protection: IP20\u003cbr\u003eFast and convenient service via Quick-Release Service Panel\u003cbr\u003eSuitable for DEYE 30–125 kW HV inverters and 100\/125 kW PCS\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003eHigh voltage modular system\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eIt is important to note that despite the nominal voltage of\u003cstrong\u003e51.2 V on the individual GB-W-Pack12-2-A3 module\u003c\/strong\u003e, GB-W is\u003cstrong\u003ehigh voltage battery system\u003c\/strong\u003e. The required system DC voltage is obtained by connecting multiple battery modules in series.\u003c\/p\u003e\n\u003cp\u003eThe following configurations are possible:\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem\u003c\/th\u003e\n\u003cth\u003eModules\u003c\/th\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003cth\u003eNominal energy\u003c\/th\u003e\n\u003cth\u003eUsable energy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGB-W60\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e256 VDC\u003c\/td\u003e\n\u003ctd\u003e60.1 kWh\u003c\/td\u003e\n\u003ctd\u003e54.1 kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGB-W72\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e307.2 VDC\u003c\/td\u003e\n\u003ctd\u003e72.1 kWh\u003c\/td\u003e\n\u003ctd\u003e64.9 kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGB-W84\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e358.4 VDC\u003c\/td\u003e\n\u003ctd\u003e84.2 kWh\u003c\/td\u003e\n\u003ctd\u003e75.8 kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGB-W96\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e409.6 VDC\u003c\/td\u003e\n\u003ctd\u003e96.2 kWh\u003c\/td\u003e\n\u003ctd\u003e86.6 kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGB-W108\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e460.8 VDC\u003c\/td\u003e\n\u003ctd\u003e108.2 kWh\u003c\/td\u003e\n\u003ctd\u003e97.4 kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGB-W120\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e512 VDC\u003c\/td\u003e\n\u003ctd\u003e120.3 kWh\u003c\/td\u003e\n\u003ctd\u003e108.2 kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGB-W132\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e563.2 VDC\u003c\/td\u003e\n\u003ctd\u003e132.3 kWh\u003c\/td\u003e\n\u003ctd\u003e119.1 kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGB-W144\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e614.4 VDC\u003c\/td\u003e\n\u003ctd\u003e144.3 kWh\u003c\/td\u003e\n\u003ctd\u003e129.9 kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGB-W156\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e665.6 VDC\u003c\/td\u003e\n\u003ctd\u003e156.4 kWh\u003c\/td\u003e\n\u003ctd\u003e140.7 kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGB-W168\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e716.8 VDC\u003c\/td\u003e\n\u003ctd\u003e168.4 kWh\u003c\/td\u003e\n\u003ctd\u003e151.6 kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGB-W180\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e768 VDC\u003c\/td\u003e\n\u003ctd\u003e180.4 kWh\u003c\/td\u003e\n\u003ctd\u003e162.4 kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGB-W192\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e819.2 VDC\u003c\/td\u003e\n\u003ctd\u003e192.5 kWh\u003c\/td\u003e\n\u003ctd\u003e173.2 kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe usable energy in the table corresponds to the recommended one\u003cstrong\u003e90% depth of discharge (DoD)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003eCharging and discharging\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eMaximum continuous system current: 230 A\u003cbr\u003ePeak system current: 322 A for 1 second\u003cbr\u003eRecommended depth of discharge: 90%\u003cbr\u003eOperating temperature when charging: 0°C to +55°C\u003cbr\u003eDischarge operating temperature: -20°C to +55°C\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003eSafety and thermal management\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eDEYE places particular emphasis on the safety of the GB-W. The system combines several levels of protection:\u003c\/p\u003e\n\u003cp\u003eThermal insulation at cell level\u003cbr\u003eAerosol fire extinguishing system at battery pack level\u003cbr\u003eDual temperature monitoring of cells and electrical connections\u003cbr\u003eNatural air cooling\u003cbr\u003eDirectional air ducts\u003cbr\u003eDust filtration\u003cbr\u003eTemperature difference between the cells below 6°C under the intended conditions\u003c\/p\u003e\n\u003cp\u003eThis architecture helps maintain a uniform temperature between the cells, which is important for the long-term performance and service life of the battery system.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003eSmart management\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eGB-W uses\u003cstrong\u003ebalancing both at the battery pack and individual cell level\u003c\/strong\u003e. DEYE also points to an integrated interaction between\u003cstrong\u003eBMS + EMS\u003c\/strong\u003e, which enables real-time monitoring and management of the energy system.\u003c\/p\u003e\n\u003cp\u003eFor the overall GB-W system are specified:\u003c\/p\u003e\n\u003cp\u003eCAN communication\u003cbr\u003eRS485 communication\u003cbr\u003eLocal Bluetooth access\u003cbr\u003eRemote access via Cloud platform\u003cbr\u003e24\/7 monitoring\u003cbr\u003eFault diagnosis\u003cbr\u003eRemote update\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003eEasy installation and service\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eOne of the distinguishing features of the GB-W series is\u003cstrong\u003ethe modular stacking construction\u003c\/strong\u003e, designed for quick and convenient installation with minimized external wiring between the main battery components.\u003c\/p\u003e\n\u003cp\u003eThe GB-W-Pack12-2-A3 itself features\u003cstrong\u003eQuick-Release Service Panel\u003c\/strong\u003e. According to DEYE, this allows certain serviceable components to be replaced directly in the built cluster without the need to dismantle the entire battery pack.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003eSystem components\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\n\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eGB-W-Pack12-2-A3\u003c\/strong\u003e– battery module 12.03 kWh\u003cbr\u003e\u003cstrong\u003eGB-W-PDU-2\u003c\/strong\u003e– PDU unit, 200–1000 VDC \/ 230 A\u003cbr\u003e\u003cstrong\u003eGB-W-Base\u003c\/strong\u003e– base\u003cbr\u003e\u003cstrong\u003eTop Cover\u003c\/strong\u003e– top cover\u003cbr\u003e\u003cstrong\u003eTelescopic Slide Rail\u003c\/strong\u003e– telescopic rail with a stroke of 150–200 mm\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003eLife and warranty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eSystem life cycle:\u003cstrong\u003e≥6000 cycles\u003c\/strong\u003e\u003cbr\u003eConditions: 25 ±2°C, 0.5C \/ 0.5C, 70% EOL\u003cbr\u003eRecommended DoD: 90%\u003cbr\u003eBattery System Warranty:\u003cstrong\u003e10 years\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eDEYE positions the GB-W to work with high voltage inverters and PCS solutions in the range\u003cstrong\u003e30–125 kW\u003c\/strong\u003e. Page 7 of the brochure presents sample HESS configurations with:\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;DEYE 30 \/ 35 \/ 40 kW Hybrid Inverter\u003cbr\u003e\u0026nbsp;DEYE 50 kW Hybrid Inverter\u003cbr\u003e\u0026nbsp;DEYE 60 \/ 70 \/ 80 kW Hybrid Inverter\u003cbr\u003e\u0026nbsp;DEYE 100 \/ 125 kW Hybrid Inverter\u003cbr\u003e\u0026nbsp;DEYE 100 \/ 125 kW PCS + MPPT\u003c\/p\u003e\n\u003cp\u003eThe exact number of battery modules should be selected according to the operating range of the battery input of the particular inverter\/PCS and official DEYE recommendations.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eHigh capacity residential ESS systems\u003cbr\u003eSmall and medium commercial and industrial C\u0026amp;I systems\u003cbr\u003ePhotovoltaic systems with energy storage\u003cbr\u003eHybrid On-Grid \/ Off-Grid systems\u003cbr\u003eBackup power supply\u003cbr\u003eOptimization of own consumption\u003cbr\u003e\u0026nbsp;Peak Shaving\u003cbr\u003e\u0026nbsp;Energy Arbitrage\u003cbr\u003eSystems with DEYE high voltage hybrid inverters\u003cbr\u003eSystems with DEYE PCS\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe GB-W-Pack12-2-A3 is a separate battery module from the DEYE GB-W system and is not a standalone 12.03 kWh battery for direct connection to a standard 48 V \/ 51.2 V low voltage inverter.\u003c\/strong\u003eThe modules are designed to sequentially build a high-voltage GB-W battery cluster together with the necessary system components.\u003c\/p\u003e\n\u003cp\u003eWe inform you that, despite our efforts, we cannot guarantee that the published information and photos do not contain inaccuracies or errors that cannot be a legal basis for claims.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003eTechnical characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e✅ Model: GB-W-Pack12-2-A3\u003cbr\u003e✅ Type: High voltage battery module for DEYE GB-W\u003cbr\u003e✅ Chemical composition of cells: LiFePO₄ (LFP)\u003cbr\u003e✅ Nominal energy: 12.03 kWh\u003cbr\u003e✅ Nominal capacity: 235 Ah\u003cbr\u003e✅ Nominal voltage: 51.2 VDC\u003cbr\u003e✅ Maximum charge\/discharge current: 230 A\u003cbr\u003e✅ Degree of protection: IP20\u003cbr\u003e✅ Charging temperature: 0°C to +55°C\u003cbr\u003e✅ Discharge temperature: -20°C to +55°C\u003cbr\u003e✅ Storage temperature: -30°C to +60°C\u003cbr\u003e✅ Dimensions (W × D × H): 690 × 436 × 270.5 mm\u003cbr\u003e✅ Weight: 92.2 kg\u003c\/p\u003e\n\u003ch3\u003eAdditional information\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGuarantee\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 years\/6000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Deye","offers":[{"title":"Default Title","offer_id":55260798583130,"sku":"GB-W-Pack12-2-A3","price":2203.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/6597\/2058\/files\/WhatsApp-Image-2026-09-10-at-16.53.14.jpg?v=1795615675","url":"https:\/\/www.airlux.bg\/en\/products\/deye-gb-w-pack12-2-a3-235ah-12-03kwh-51-2vdc-230a-ip20","provider":"ЕЪРЛУКС - Отопление, Вентилация и Климатизация","version":"1.0","type":"link"}